(a) fan does not rotate
1, not turn on the power-processing power
2, motor doesn't work-check motor wiring or replacement motor
3, fan head damage repair fan or replacement.-
4, fan of foreign card dead-removal
(2) the noise increased
1, bearing and bearing grease lubrication, dry
2, bearing damage--change bearing
3, impeller, replace or pump impeller wear head
4, strong a loose or fall off-tight fasteners
5, fan-there were foreign body removal or replacement pump head
(3) increase vibration
1, bearing damage--change bearing
2, the impeller don't balance-remove the impeller foreign or school static and dynamic balance
3, main shaft deformation, spindle or replacement pump head
4, condition into turbulent earthquake zone-working status, avoid turbulent adjustment to the quake zone
5, in and out carbon monoxide into mesh jam-clean screen pack
(4) temperatures
1, inlet temperature is too high-lower inlet temperature
2, bearing and bearing grease lubrication, dry
3, fan-clear way to low efficiency, dust or replacement pump head
4, condition change-adjust working state
5, environmental temperature increases-increasing environmental ventilation cooling
(5) pressure decrease
1, pump head speed reduce power supply voltage, low fault or motor
2, and the pipeline resistance increases-lower resistance of pipelines
3, condition change-adjust working state
4, motor to reverse-motor to wiring
(6) flow decrease
1, import and export gas filter jam-clean screen pack
2, pump head speed reduce power supply voltage, low fault or motor
3, and the pipeline resistance increases-lower resistance of pipelines
4, working status-adjust working state. Increase
5, motor to reverse-motor to wiring